Tailored to meet the needs of high-end laboratories
Sample Throughput: 96
Maintenance-free LED Light Source
6 Flourescence Channels for Gentier 96E / 4 Flourescence Channels for Gentier 96R
Maximum heating ramp rate ≥6.1°C/s
Maximum cooling ramp rate ≥5.0°C/s
Temperature accuracy ±0.1°C
10.4-inch full-color touch screen
Stand alone operations or control via PC
Stand-alone data storage for at least 1000 experiments
Absolute / Relative Qualitative analysis
End-Point Fluorescence Analysis
Melting Curve Analysis
International Approval and Certification: UK, EU, USA, China
Gentier 96T PCR Thermal Cycler
Sample Throughput: 96
Maximum heating ramp rate ≥5.5°C/s
Temperature accuracy ±0.1°C
7-inch TFT true colour LCD Touch Screen
Preset multiple experimental program templates
Power failure protection desin
Conventional PCR
Reverse transcription PCR
Gradient PCR
Long-range PCR
Up to 12 temperature gradients
Gentier 48E/48R - Real-Time PCR System
Designed for small - medium sizeds laboratories, field testing and mobile laboratories
Immediate Analysis of Experimental Data on the Instrument
Direct printing function by connecting to a thermal printer
Maintenance-free LED Light Source
4 Flourescence Channels for Gentier 48E / 2 Flourescence Channels for Gentier 48R
Maximum heating ramp rate ≥8.0°C/s
Maximum cooling ramp rate ≥6.2°C/s
Temperature accuracy ±0.1°C
7-inch TFT true colour LCD Touch Screen
Stand Alone operations or control via PC
Stand alone data storage for at least 1000 experiments
Absolute / Relative Qualitative analysis
End-Point Fluorescence Analysis
Melting Curve Analysis
International Approval and Certification: UK, EU, USA, China
Nucleic Acid Extractors
Gene Rotex 96/48 Nucleic Acid Extractor
Sample Throughput: 96/48
Reccommended Sample Volume: 200µL / 1000µL
Sample Type: Serum, Plasma, Whole Blood, swab medium, amniotic fluid, feces, animal and plant tissues, FFPE sections, bacteria, fungi etc.
Libex Nucleic Acid Extractor
Sample Throughput: 32
Reccommended Sample Volume: 200µL
Sample Type: Serum, Plasma, Whole Blood, swab medium, amniotic fluid, feces, animal and plant tissues, FFPE sections, bacteria, fungi etc.
Workstations & Autosamplers
PANA 9600S
Automated Nucleic Acid Workstation
PANA 9600S Automated Nucleic Acid Workstation is designed and developed based on the principles of nucleic acid extraction by magnetic bead method and rotary nucleic acid extraction technology and integrates sample information scanning, sample loading, nucleic acid extraction kits.
GeneMix 48
Automated Sample Processing System
Tianlong GeneMix 48 Automatic Sample Processing System is a truly automated system that integrates tube lid opening/closing, sample dispensing, proteinase K/internal reference adding of 48 sample tubes in one go, frees you from tedious procedures, and offers optimised efficiency and safety.
Sample Throughput: 48
PANA S401/S201
Automated Pipetting Workstation
Tianlong PANA S401/S201 Automated Pipetting Workstation can complete the automated PCR setup for 96 samples within 10 minutes, and is suitable for pipetting in nucleic acid detection with optimised detection capabilities and efficiency.
Reagent Kits
Nucleic Acid Extraction Kits
Tianlong offers a range of over 40 superior reagents based on the magnetic-bead method for the extraction of nucleic acids from:
Whole Blood
Serum
Plasma
Swabs
Feces
Animal & Plant Tissue
These products are CE-Certified among many other official certifications in USA (FDA), China (NMPA), South Korea (KFDA).
Real Time PCR Kits
Tianlong offers more than 40 kinds of real-time PCR reagents, designed for the diagnosis and testing for the following:
Respiratory Diseases
Prenatal & Postnatal Care
Digestive Diseases
Genetic Diseases
Cancers
Pharmacogenomic Testing
All of the reagents have obtained approval in the UK, China, EU, among other regions throughout the world.
For Specifications of each kit – please click here.
Sample Collection Set
Tianlong Sample Collection Set include collection tubes with specimen transport media (STM) (inactivated and non-inactivated_ and swabs (Oropharyngeal and nasopharyngeal) applicable for single sample collection or multiplex sampling.