Evosep Proteomics / Evotip Pure
Consumable
A high-efficiency disposable trap column that combines desalting with LC-MS sample introduction. One step instead of three — which removes carryover, protects the analytical column, and lets a prepared sample wait 28 days for instrument time without degrading.
How it works
In a conventional workflow, peptides are desalted, dried, resuspended and transferred to a vial before injection. Every one of those steps loses sample to plastic and adds a chance to go wrong.
Evotip Pure replaces them. Peptides are loaded directly onto the tip, where they are desalted and immobilised. The Evosep system then partially elutes them — taking the peptides you want to measure and leaving large, hydrophobic molecules behind on the tip, which is discarded. That single design decision is what produces the three things this page is about: no carryover, a long-lived analytical column, and a sample that can sit on the bench until the mass spectrometer is free.
Loading capacity is 1 µg. Because desalting is integrated with elution, less starting material is needed than in a traditional workflow where offline desalting and elution happen separately.
Evotip Pure integrates peptide purification with sample loading and elution. Source: AN-022D, Figure 1.
Single-use trap columns mean the injection system carries nothing from one sample to the next.
Partial elution keeps large, hydrophobic molecules off the analytical column, so it lasts.
Less exposure of peptides to plastic surfaces, which directly improves recovery.
Prepare hundreds of samples now, analyse them when the instrument is free.
Carryover and robustness
Carryover is the failure mode that quietly ruins a large cohort: a trace of the previous sample turning up in the next one, most damaging exactly when the next sample is small. A disposable trap removes the mechanism.
Backpressure creeping upward over a long run is how a column tells you it is collecting material it cannot release. Across close to 500 LC-MS experiments on the 200 SPD method, the pressure stayed consistent — evidence that partial elution is doing its job and large hydrophobic molecules are leaving with the tip rather than accumulating on the column.
At cohort scale. In a separate study of an automated plasma pipeline, carryover stayed below 0.2% across more than 1,100 patient plasma samples — 1,392 injections including controls — analysed in under seven days (AN-041A).
Sources: AN-022D and AN-032B in the literature room.
Sample storage
The scheduling constraint in most labs is not preparation capacity — it is mass spectrometer time. Loaded Evotips can wait, which lets you prepare in batches that suit the chemistry rather than the queue.
HeLa digest loaded at 5 ng and 50 ng was analysed immediately and up to 28 days later. Precursor identification rates varied slightly across the period, with no systematic losses over time (AN-022D).
At single-cell-equivalent loads of 250 pg, more than 90% of precursor identifications were preserved after 48 hours of on-tip storage, and close to 75% after 72 hours (AN-032B).
In an automated end-to-end workflow with samples stored in 0.1% formic acid at 4 °C, no significant sample loss was seen for up to nine days (AN-040A).
The comparison that makes the case. In a controlled test, a sample was held in a sample plate for a few seconds before Evotip loading — one extra transfer step. Even at a relatively generous 50 ng HeLa load, that step caused significant losses, most pronounced in the middle and hydrophobic part of the gradient where peptides stick to plastic. The tip is not just storage; it is one fewer surface.
Low input and single cell
Most autosamplers rely on a sample loop, which sets a floor on how small a volume can be injected sensibly. Evotip Pure works the other way round: dilute samples are concentrated onto the tip as they load.
Evotip Pure addresses the analytical challenges specific to high-sensitivity workflows — capture, recovery and storage of very small peptide amounts. Source: AN-032B, Figure 1.
End-to-end automation
Conventional liquid handling automates digestion well but stalls at post-digestion processing. Loading Evotips directly on the liquid handler closes that gap — digestion, clean-up and storage become one hands-free process.
In a controlled comparison, half the samples from a PAC digestion were loaded straight onto Evotips from the sample plate; the other half were dried in a vacuum centrifuge and resuspended in 0.1% formic acid first — the traditional route.
Directly loaded samples showed higher summed precursor intensities. The difference was most pronounced for hydrophobic peptides eluting late in the gradient, which is precisely where adsorption to plastic does its damage. Notably, direct loading at 10% of the digest outperformed reconstituted samples at 20%.
Automated Evotip loading protocols are published for the platforms most labs already own, each with its own application note in the literature room:
Step-by-step protocols and scripts for each platform are published by Evosep at evosep.com/support/automation.
Specifications and ordering
| Format | Single-use disposable trap column, supplied in boxes of 96 |
| Loading capacity | 1 µg |
| Function | Integrated desalting and LC-MS sample introduction, with partial elution |
| Storage window | Up to 28 days loaded, with no systematic loss |
| Recommended storage | Submerged in solvent A, or in 0.1% formic acid at 4 °C |
| Low-input range | Demonstrated down to 250 pg single-cell-equivalent loads |
| Compatibility | Evosep One and Evosep Eno; on-deck loading on OT-2, AssayMAP Bravo and Biomek i5/i7 |
| Part number | Pack size | Tips |
|---|---|---|
| EV2011 | 1 box | 96 tips |
| EV2013 | 10 boxes | 960 tips |
| EV2015 | 50 boxes | 4,800 tips |
| EV2018 | 100 boxes | 9,600 tips |
Evotips are included in Evokit sample preparation kits for Evosep Lupo. Contact us for pricing and availability.
Go deeper
Carryover, quantitative reproducibility, retention time stability and 28-day storage recovery across 480 injections of HeLa and plasma digest.
PDF · 4 pagesOpen in the literature room → Application note · AN-032BLoading volume, DDM, carryover into single-cell-equivalent samples, and stability across 340 runs and three days of on-tip storage.
PDF · 4 pagesOpen in the literature room → Application note · AN-040ADirect loading versus dried and reconstituted samples, plus the tip, reagent and recovery consequences of removing transfer steps.
PDF · 4 pagesOpen in the literature room →Where the Evotip goes next: ten standardized methods, performance data and technical specifications.
Explore Evosep Eno → Product pageEvokit workflows that end with a loaded, ready-to-analyse Evotip and a full traceability record.
Explore Evosep Lupo →Get started
Talk to a specialist about how Evotip Pure fits your sample types, your liquid handler and your throughput.